Hamden, Conn., Mun. Code Ch. 152 § 152.46

TOTAL WINDOW AREA

In Force
Verified 11/11/2026 · Next check 12/11/2026
HamdenHabitability & Repair

Operative Text

Hamden, Conn., Mun. Code Ch. 152 § 152.46
(A) Every habitable room shall have at least one window or skylight facility directly to the outdoors. The minimum total window area, measured between stops, for every habitable room shall be 8% of the floor area of such room. Whenever walls or other portions of structures face a window of any room and light-obstruction structures are located less than three feet from the window and extend to a level above that of the ceiling of the room, the window shall not be deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area. Whenever the only window in a room is a skylight-type window in the top of the room, the total window area of the skylight shall equal at least 15 % of the total floor area of the room.


(B) Emergency egress.


(1) Every sleeping room shall have at least one operable window or exterior door approved for emergency egress or rescue. The units must be operable from the inside to a full clear opening without the use of a key or tool. Where the windows are provided as a means of egress or rescue, they shall have a sill height of not more than 44 inches above the floor. All egress or rescue windows from sleeping rooms must have a net clear opening of 5.7 square feet. The minimum net clear opening height shall be 24 inches. The minimum net clear opening width shall be 20 inches. Grade floor windows may have a minimum net clear opening of 5.0 square feet. Existing windows shall be permitted to utilize removable sash. To achieve required opening, sash shall be capable of being removed without use of key or tool.


(2) Sliding glass doors may be considered to meet the required window area provided the required square foot area is met.


(C) Ventilation.


(1) The glazed areas need not be openable when the opening is not required by division (B)(2) above, and an approved mechanical ventilation system is provided and capable of producing 0.35 air change per hour in the room or a whole-house mechanical ventilation system is installed and capable of supplying outdoor ventilation air of 15 cubic feet per minute per occupant computed on the basis of two occupants for the first bedroom and one occupant for each additional bedroom.


(2) The glazed area may be omitted in rooms where the opening is not required by division (B)(1) above, and an approved mechanical ventilation system is provided and capable of producing 0.35 air change per hour in the room of a whole-housed mechanical ventilation system is installed and capable of supplying outdoor ventilation air of 15 cubic feet per minute per occupant computed on the basis of two occupants for the first bedroom and one occupant for each additional bedroom, and artificial light is provided capable of producing an average illumination of six foot candles over the area of the room at a height of 30 inches above the floor level.


(3) When alcove rooms open without obstruction into adjoining rooms, the required window openings to the outer air shall be based on the combined floor area of room and alcove. For the purposes of determining light and ventilation requirements, any room may be considered as a portion of the adjoining room when at least 1/2 of the area of the common wall is open and unobstructed and provides an opening of not less than 1/10 of the floor area of the interior room but not less than 25 square feet.


(Adopted 9-5-67) (Am. Ord. 491, passed 11-6-03; Am. Ord. 568, passed 1-5-09) Penalty, see § 152.199
Source: Legislative text reproduced verbatim
Plain English

Hamden Ch. 152 § 152.46 establishes minimum standards for natural light, ventilation, and emergency egress in habitable rooms. Every habitable room must have window or skylight area equal to at least 8% of the room's floor area (or 15% for skylight-only rooms), and windows blocked by nearby structures do not count toward that minimum. Sleeping rooms must additionally have at least one operable window or exterior door that allows emergency escape or rescue without a key or tool, meeting specific size and height requirements. Approved mechanical ventilation systems may substitute for openable glazing in certain circumstances.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 11, 2026

Plain English — not legal advice.

For Property Managers

Property owners and managers operating under Hamden Ch. 152 § 152.46 generally verify that each habitable room contains qualifying window or skylight area meeting the 8% floor-area threshold, ensuring that any window facing a close obstruction is not counted toward that minimum. Compliant operators confirm that every sleeping room has an operable egress window or exterior door meeting the net clear opening, sill height, and operability requirements without requiring a key or tool. Where mechanical ventilation systems are used as an alternative to openable glazing, operators typically document that those systems meet the air-change or cubic-feet-per-minute standards specified in the provision.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Under Hamden Ch. 152 § 152.46, tenants in habitable rooms are entitled to adequate natural light and, in sleeping rooms, a functional emergency egress window or door that can be opened from the inside without a key or tool. If a window is blocked by a nearby structure or fails to meet the required dimensions, it may not legally satisfy the provision's minimums. Tenants who believe their unit does not meet these standards may consider documenting the conditions, raising the violation as a defense in relevant proceedings, or contacting Hamden's housing code enforcement office; local tenant-rights organizations can also help identify available options under § 152.46.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 11, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

No inbound references recorded yet for this provision.

Related Rules

§ 244.260
Compliance required
§ 14.567
ADOPTED BY REFERENCE
§ 244.340
Sewer and water connections

Source Information

Snapshot SHA:
Fetched:Nov 11, 2026, 04:05 PM UTC