Natick, Mass., Bd. of Health Reg. ch. XI (2002) § 5

LIGHT, VENTILATION, HEATING AND EGRESS

In Force
Verified 11/11/2026 · Next check 12/11/2026
NatickHabitability & Repair

Operative Text

Natick, Mass., Bd. of Health Reg. ch. XI (2002) § 5
The owner shall be responsible for compliance with the
           provisions of all Subsection of Section 5 of these standards.

    5.1     Every habitable room shall have at least one window or
           skylight facing directly to the outdoors. The minimum total
           window or skylight area measured between stops, for every
           habitable room shall be 10 per cent of the floor area of such
           room. Whenever walls or other portions of structures face a
      window of any such room and such light-obstruction structures
      are located less than 3 feet from the window and extend to a
      level above that of the ceiling of the room, such a window
      shall not be deemed to face directly to the outdoors and shall
      not be included as contributing to the required minimum total
      window area.

5.2   Every habitable room shall have at least one window or
      skylight which can be easily opened. The total openable
      window area in every habitable room shall be equal to at least
      45 per cent of the minimum window area or minimum skylight
      area, as required in Subsection 5.1 of Section 5 of these
      minimum standards except where there is supplied some other
      device affording adequate ventilation and approved by the
      Board of Health.

5.3   Every bathroom and water closet compartment shall be well
      lighted and ventilated. Three foot candles of light three
      lumens per square foot) shall be provided by either natural or
      artificial means and shall be available at all times. Such light
      shall be measured 36 inches from the floor at the center of the
      room. Every bathroom and water closet compartment shall
      have at least one window or skylight which can be easily
      opened. The total openable window area shall be equal to at
      least forty-five per cent of the minimum window area or
      minimum skylight area as required in Subsection 5.1 of
      Section 5 of these minimum standards. Such window area
      requirements of this section may be waived provided that there
      is an installed mechanical ventilation system approved by the
      Board of Health.

5.4   Where there is electric service available from power lines
      which are not more than 300 feet away from a dwelling, every
      habitable room shall contain at least two separate wall type
      electric convenience outlets, or one such convenience outlet
      and one ceiling or wall type electric light fixture. Every such
      outlet and fixture shall be properly installed, shall be
      maintained in good and safe working condition, and shall be
      connected to the source of electric power in a safe manner. No
      temporary wiring shall be used except extension cords which
          run directly from portable electrical fixtures to convenience
          outlets, and which do not lie under rugs or other floor
          coverings, nor extend through doorways, transoms or other
          openings through structural elements.

    5.5   Every portion of any interior passageway or staircase common
          to two or more families in a building used for human
          habitation shall be illuminated naturally or artificially at all
          times with an illumination of at least two lumens per square
          foot (2 foot candles) in the darkest portion of the normally
          traveled stairs and passageways. Such means of illumination
          in dwellings occupied by three families or less may be
          controlled by switches that may be turned on as needed.

    5.6   Every means of egress from a dwelling unit or a lodging unit
          shall be safe and unobstructed.

    5.7   Every dwelling shall have heating facilities which are properly
          installed, are maintained in safe and good working condition,
          are capable of safely and adequately heating all habitable
          rooms, bathrooms and water closet compartment located
          therein to a temperature of at least 70 degrees Fahrenheit under
          ordinary minimum winter conditions. The temperature shall
          be read at a height of three feet above floor level at the center
          of the room. Such heating equipment shall be installed and
          maintained in accordance with the applicable regulations of the
          Board of Fire Prevention Regulations of the Massachusetts
          Department of Public Safety.

    5.8   Space heaters, except electrical, shall be properly vented to a
          chimney or duct leading to outdoors.
Source: Legislative text reproduced verbatim
Plain English

Section 5 of the Natick Board of Health Regulation Ch. XI establishes minimum standards for light, ventilation, heating, and egress in residential dwellings. Habitable rooms must meet specific window area and openability requirements, bathrooms must be lit and ventilated to defined levels, electrical outlets must meet minimum counts and safety standards, common passageways must be illuminated, all egress paths must remain safe and clear, and heating systems must be capable of maintaining at least 70°F under ordinary winter conditions. Responsibility for compliance with all subsections of Section 5 rests with the property owner.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 11, 2026

Plain English — not legal advice.

For Property Managers

Under Section 5 of Natick Board of Health Reg. Ch. XI, compliant property owners generally ensure that every habitable room has windows or skylights meeting the 10% floor-area threshold and that at least 45% of that area is openable, or that a Board of Health–approved ventilation device is in place. Owners also maintain safe, properly installed electrical outlets and fixtures in each habitable room (where power lines are within 300 feet), keep common stairways and passageways illuminated to at least 2 foot-candles at all times, and verify that heating systems can reach 70°F at the three-foot measurement height during winter. Space heaters that are not electric must be vented to a chimney or outdoor duct, and all egress paths must remain unobstructed at all times.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Section 5 of Natick Board of Health Reg. Ch. XI gives tenants the right to live in units that meet defined minimums for natural light, ventilation, electrical safety, common-area lighting, heating, and safe exit paths. If a habitable room lacks adequate windows, a bathroom is poorly lit or unventilated, heating cannot reach 70°F, or an exit is blocked, these conditions may constitute violations of the regulation. Tenants who believe their unit falls short of these standards can document the conditions, contact the Natick Board of Health to request an inspection, or reach out to a local tenant-rights organization to understand available options.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 11, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

No inbound references recorded yet for this provision.

Related Rules

§ 244.260
Compliance required
§ 14.567
ADOPTED BY REFERENCE
§ 244.340
Sewer and water connections

Source Information

Snapshot SHA:
Fetched:Nov 11, 2026, 03:20 AM UTC