Minneapolis, Minn., Code of Ordinances § 12 § 244.920

Fire extinguishers (Minneapolis Housing Code)

In Force
Verified 9/15/2026 · Next check 12/14/2026
MinneapolisHabitability & Repair

Operative Text

Minneapolis, Minn., Code of Ordinances § 12 § 244.920
(a) [ When required; location. ] In all multiple dwellings having three (3) or more dwelling units and in all dormitories, convents, monasteries, hotels, lodging or rooming houses, fraternity and sorority houses, or in other similar buildings containing more than ten (10) sleeping rooms or occupied by more than twenty (20) persons, there shall be supplied on each floor, including the basement or cellar, one fire extinguisher for every six thousand (6,000) square feet of floor area or fraction thereof. All hand fire extinguishers shall be conspicuously and conveniently located so that the extinguisher is not more than five (5) feet, nor less than two (2) feet, above the floor in public halls or corridors and so maintained as to be in good working condition at all times. Providing that in no case shall the occupant of any dwelling or rooming unit have to travel more than seventy-five (75) feet from the entrance of the occupant's unit to reach a fire extinguisher. Fire extinguishers shall be a minimum of Class 2A-10BC or an equivalent approved by the fire department.
(b) [ Portable extinguishers. ] Whenever portable fire extinguishers are required by this code, the person who owns or controls such extinguisher shall comply with the following: A portable stored pressure fire extinguisher equipped with pressure indicators or gauge shall be inspected and maintained by a licensed serviceworker not less than once every two (2) years. All other portable fire extinguishers shall be serviced or recharged not less than once each year. All such fire extinguishers shall meet all requirements and specifications as set forth in National Fire Protection Association Pamphlet No. 10, Installation of Portable Fire Extinguishers, copies of which are on file in the offices of the city clerk and the fire department.
(c) [ Discontinuance of inverted-type extinguishers. ] The use of inverted-type fire extinguishers shall be discontinued and they shall be discarded. "Inverted-type fire extinguisher" means all fire extinguishers that require the device to be turned upside down to be activated. This includes soda acid, foam, water cartridge and loaded stream cartridge fire extinguishers. No person shall hydrostatically test any inverted-type fire extinguisher.
(d) [ Tampering with or removal. ] No person shall tamper with, meddle with, remove, empty, damage or destroy any extinguisher except in the event of fire or authorized inspection. (Code 1960, As Amend., § 75.040; 78-Or-244, § 35, 11-22-78; Pet. No. 252271, § 24 , 5-11-90; 92-Or-176 , § 1, 12-18-92)
Source: Legislative text reproduced verbatim
Plain English

Minneapolis, Minn., Code of Ordinances § 244.920 establishes detailed requirements for fire extinguisher placement, maintenance, and use in multi-unit residential buildings and similar group-occupancy structures. Buildings meeting the thresholds in the ordinance must have at least one extinguisher per 6,000 square feet on every floor, mounted between two and five feet off the ground in public hallways, and never more than 75 feet from any unit entrance. Extinguishers must meet minimum Class 2A-10BC ratings, be serviced on a regular schedule by licensed workers, and inverted-type extinguishers are entirely prohibited. Tampering with, removing, or damaging any extinguisher—outside of an actual fire or authorized inspection—is also prohibited.

Written by anthropic/claude-sonnet-4.6 · Reviewed on September 15, 2026

Plain English — not legal advice.

For Property Managers

Property owners and managers subject to § 244.920 generally ensure that compliant fire extinguishers are installed on every floor, including basements, at the required density and mounting height in public corridors. A compliant operator keeps records of annual or biennial servicing by a licensed serviceworker, depending on extinguisher type, and verifies that all units meet the NFPA Pamphlet No. 10 specifications referenced in the ordinance. Operators also confirm that no inverted-type extinguishers remain in service and that extinguishers are never relocated or altered except during authorized inspections.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Under § 244.920, tenants in covered buildings have a right to accessible, properly maintained fire extinguishers within 75 feet of their unit entrance at all times. If an extinguisher appears missing, damaged, out of service, or improperly mounted, tenants can document the condition and report it to the Minneapolis Department of Regulatory Services or the city's fire department, which oversees compliance with this provision. Tenant-rights organizations in Minneapolis can also help residents understand how to raise a housing code violation as part of a broader habitability concern.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated September 15, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

No inbound references recorded yet for this provision.

Related Rules

§ 8.60.130
Severability
§ 15.12.010
Definitions
§ 15.12.240
Temporary housing

Source Information

Snapshot SHA:
Fetched:Sep 15, 2026, 09:30 PM UTC