Crawford, N.Y., Code of Ordinances ch. 103 (eCode360 ed. 2026) § 103-6
A. General. The exterior of a structure shall be maintained in good repair, structurally sound and sanitary so as not to pose a threat to the public health, safety or welfare. B. Protective treatment. All exterior surfaces, including, but not limited to, doors, door and window frames, cornices, porches, trim, balconies, decks and fences shall be maintained in good condition. Exterior wood surfaces, other than decay-resistant woods, shall be protected from the elements and decay by painting or other protective covering or treatment. Peeling, flaking and chipped paint shall be eliminated and surfaces repainted. All siding and masonry joints as well as those between the building envelope and the perimeter of windows, doors, and skylights shall be maintained weather resistant and watertight. All metal surfaces subject to rust or corrosion shall be coated to inhibit such rust and corrosion, and all surfaces with rust or corrosion shall be stabilized and coated to inhibit future rust and corrosion. Oxidation stains shall be removed from exterior surfaces. Surfaces designed for stabilization by oxidation are exempt from this requirement. C. Structural members. All structural members shall be maintained free from deterioration, and shall be capable of safely supporting the imposed dead and live loads. D. Foundation walls. All foundation walls shall be maintained plumb and free from open cracks and breaks and shall be kept in such condition so as to prevent the entry of rodents and other pests. E. Exterior walls. All exterior walls shall be free from holes, breaks and loose or rotting materials; and maintained weatherproof and properly surface coated where required to prevent deterioration. F. Roofs and drainage. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance. G. Decorative features. All cornices, beltcourses, corbels, terra cotta trim, wall facings and similar decorative features shall be maintained in good repair with proper anchorage and in a safe condition. H. Overhang extensions. All overhang extensions including, but not limited to canopies, marquees, signs, metal awnings, fire escapes, standpipes, and exhaust ducts shall be maintained in good repair and be properly anchored so as to be kept in a sound condition. When required, all exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment. I. Stairways, decks, porches and balconies. Every exterior stairway, deck, porch and balcony, and all appurtenances attached thereto, shall be maintained structurally sound, in good repair, with proper anchorage and capable of supporting the imposed loads. J. Chimneys and towers. All chimneys, cooling towers, smoke stacks, and similar appurtenances shall be maintained structurally safe and sound, and in good repair. All exposed surfaces of metal or wood shall be protected from the elements and against decay or rust by periodic application of weather-coating materials, such as paint or similar surface treatment. K. Handrails and guards. Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition. L. Window, skylight and door frames. Every window, skylight, door and frame shall be kept in sound condition, good repair and weathertight. (1) Glazing. All glazing materials shall be maintained free from cracks and holes. (2) Openable windows. Every window, other than a fixed window, shall be easily openable and capable of being held in position by window hardware. M. (Reserved) N. Doors. All exterior doors, door assemblies and hardware shall be maintained in good condition. Locks at all entrances to dwelling units, rooming units and guestrooms shall tightly secure the door. Locks on means of egress doors shall be in accordance with the State Property Maintenance Code. O. Basement hatchways. Every basement hatchway shall be maintained to prevent the entrance of rodents, rain and surface drainage water. P. Guards for basement windows. Every basement window that is openable shall be supplied with rodent shields, storm windows or other approved protection against the entry of rodents.
Source: Legislative text reproduced verbatim
Plain English

Crawford, N.Y., Code of Ordinances ch. 103 § 103-6 establishes comprehensive standards for the exterior condition of structures, covering everything from foundation walls and roofs to windows, doors, handrails, and decorative features. The rule requires that all exterior components be kept structurally sound, weathertight, and free from deterioration, rot, rust, and pest-entry points. Protective coatings such as paint must be applied and maintained on vulnerable surfaces, and drainage systems must function properly to prevent water damage.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 10, 2026

Plain English — not legal advice.

For Property Managers

Under Crawford, N.Y., Code of Ordinances ch. 103 § 103-6, property owners and managers generally maintain a routine inspection and maintenance schedule covering all exterior elements — including siding, roofing, gutters, foundations, windows, doors, stairways, balconies, and chimneys. Compliant operators promptly address peeling paint, cracked glazing, loose structural members, and any gaps that could allow rodent entry or water infiltration. Keeping records of repairs, painting cycles, and professional inspections helps demonstrate ongoing compliance with the provision's broad exterior-maintenance requirements.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Crawford, N.Y., Code of Ordinances ch. 103 § 103-6 establishes minimum exterior-condition standards that apply to the structure where a tenant lives, including sound walls, weathertight windows and doors, functional locks, and pest-resistant basement openings. If exterior conditions appear to fall short of these standards — such as a leaking roof, broken window frames, or deteriorating stairways — tenants may document the conditions and report them to the local code enforcement authority responsible for administering ch. 103. Tenant-rights organizations can help residents understand available options, including how a code violation might be relevant to other housing rights or remedies.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 10, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

Rules and statutes that cite this regulation

Crawford Code § 103-11
Crawford Code § 103-5

Related Rules

§ 244.290
Dwelling plumbing facilities required
§ 244.300
Shared bath dwelling unit plumbing facilities required
§ 244.310
Basement water closet

Source Information

Snapshot SHA:
Fetched:Nov 10, 2026, 12:29 AM UTC