Elmira, N.Y., Code ch. 8, art. V § 8-403
Prevention of interior fire spread
Operative Text
(a) Floors, walls, ceilings, soffits and other components required to provide a fire-resistive enclosure or separation, and construction required to protect structural members shall be maintained so that the respective fire-resistance rating of the enclosure, separation or construction is preserved. (b) In buildings of mixed occupancy, nonresidential space shall be separated from residential space by fire separations having a fire-resistance rating of at least one hour. (c) In multiple dwellings of more than two stories, floor construction above a cellar or basement shall have a fire-resistance rating of at least one hour, except such requirement shall not apply where the cellar or basement is completely protected by an automatic sprinkler system. (d) In multiple dwellings, spaces used as carpenter, repair or paint shops and spaces where flammable or combustible materials are stored shall be enclosed by construction having a fire-resistance rating of at least one hour. (e) In multiple dwellings, central kitchens shall be separated from central dining rooms by construction having a fire-resistance rating of at least one hour. (f) Self-closing devices of exit doors shall be maintained in good operating condition. Only approved-type magnetic hold-open devices connected to fire devices or objects may be used to hold open exit doors in stairway enclosures at floor landings. (g) Vending machines and other equipment or materials shall not be located in lobbies, corridors or passageways if it constitutes a fire hazard or interferes with the exit facilities. (h) A garage within or attached to a building containing a residential occupancy shall be separated from the residential portion of the building by construction capable of preventing the passage of fumes and vapors and having a fire-resistance rating as follows: For one- and two-family dwellings, at least one-half hour; for multiple dwellings, at least one hour. (i) Interior finish in enclosed exits shall have a flame-spread rating of not more than 75. (j) Draperies and decorative materials located in enclosed exits or public spaces shall be noncombustible or flame-resistant.
Elmira Code ch. 8, art. V § 8-403 establishes a set of fire-containment standards for residential and mixed-use buildings. The rule requires that fire-resistive walls, floors, ceilings, and other structural components be kept in a condition that preserves their rated ability to slow the spread of fire. It also sets minimum one-hour fire-resistance ratings between residential and nonresidential spaces, around hazardous storage areas, and between garages and living areas, while restricting the materials and equipment allowed in corridors and exit pathways.
Plain English — not legal advice.
Operators of residential and mixed-use properties in Elmira are generally expected to conduct regular inspections of fire-rated assemblies—walls, floors, ceilings, and soffits—to confirm that penetrations, damage, or deterioration have not compromised the ratings required under § 8-403. Compliant managers typically ensure that self-closing devices on exit doors function properly, that no vending machines or other obstructions create fire hazards in corridors, and that interior finishes and draperies in exits meet the flame-spread and flame-resistance thresholds the provision specifies. Buildings with attached garages, mixed occupancies, or basement spaces should have documentation confirming that separations meet the applicable fire-resistance ratings outlined in § 8-403.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
Elmira Code ch. 8, art. V § 8-403 gives tenants a basis to raise concerns when fire-rated barriers, self-closing exit doors, or corridor conditions appear to be compromised or out of compliance. Tenants who observe damaged fire walls, propped-open stairway doors, blocked corridors, or flammable decorations in exit areas may report these conditions to the City of Elmira's code enforcement office. Tenant-rights organizations can help residents understand how documented violations under § 8-403 may be relevant to habitability concerns or other proceedings.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated November 6, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.
Effective Timeline
References Out
No outbound references recorded yet for this provision.
References In
Rules and statutes that cite this regulation
Related Rules
Source Information
Use this in your app
Access this data programmatically via our API