Fallsburg, N.Y., Code of Ordinances ch. 156 (eCode360 ed. 2026) § 156-18

Interior protection

In Force
Verified 11/10/2026 · Next check 12/10/2026
FallsburgSpecific Conditions

Operative Text

Fallsburg, N.Y., Code of Ordinances ch. 156 (eCode360 ed. 2026) § 156-18
A. Crawl spaces shall be maintained free of moisture and the flow of air from such spaces into walls above shall be effectively barred so as to prevent deterioration of structural members. Such provisions shall consist of maintenance of openings in foundation walls to provide adequate circulation of air in the crawl space, covering the ground in the crawl space with a moisture barrier, installation of drains outside the structure if the crawl space is below surrounding grade, blocking openings in stud walls to prevent flow of air and moisture into walls, frequent destruction of termite tubes from the soil to wood floor members above, poison treatment of soil, and other suitable means. B. Structural members shall be maintained so as to be structurally sound. Such protection shall consist of shoring, reinforcement, or repair where necessary, frequent destruction of termite tubes or other appropriate means. C. Chimneys and flues shall be maintained so as to be structurally sound and to prevent leakage of gases into the structure. Such maintenance shall consist of clearing flue stoppages, sealing open joints, repairing masonry where necessary and other suitable means. D. Ceilings and walls shall be maintained so that parts which become loose or defective do not constitute a hazard to occupants. Such maintenance shall consist of removing and replacing loose or defective sections. E. Toilet room and bathroom floors shall be maintained so as to prevent leakage of water through the floor, under normal conditions of use and floor washing, and resultant deterioration or defects in structural members and ceilings below. Maintenance shall consist of repairs which effectively provide the moisture and waterproof qualities required for the particular floor.
Source: Legislative text reproduced verbatim
Plain English

Fallsburg, N.Y., Code of Ordinances ch. 156 § 156-18 establishes interior structural protection standards for residential properties. The rule requires that crawl spaces, structural members, chimneys and flues, ceilings, walls, and bathroom floors all be kept in sound, safe condition through a range of specified maintenance practices. The provision identifies particular methods—such as moisture barriers, termite control, flue clearing, and waterproofing—as acceptable means of meeting these standards, though other suitable approaches may also qualify.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 10, 2026

Plain English — not legal advice.

For Property Managers

Under Fallsburg, N.Y., Code of Ordinances ch. 156 § 156-18, compliant property operators generally conduct routine inspections of crawl spaces, structural framing, chimneys, interior walls, ceilings, and bathroom floors. Operators typically address identified deficiencies promptly—installing moisture barriers, shoring structural members, sealing flue joints, replacing loose ceiling or wall sections, and repairing bathroom floor waterproofing as needed. Maintaining documentation of these maintenance activities can help demonstrate ongoing compliance with the provision's requirements.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Fallsburg, N.Y., Code of Ordinances ch. 156 § 156-18 establishes that tenants are entitled to occupy a dwelling whose crawl spaces, structural members, chimneys, walls, ceilings, and bathroom floors are maintained in a safe and sound condition. If a tenant observes conditions such as moisture intrusion, loose ceiling sections, crumbling walls, or leaking bathroom floors, those conditions may constitute a violation of this provision. Tenants who believe their housing does not meet these standards may consider contacting the local code enforcement office, raising the condition as a defense in relevant proceedings, or reaching out to a tenant-rights organization for general guidance.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 10, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

Rules and statutes that cite this regulation

Fallsburg Code § 156-3
Fallsburg Code § 156-3
Fallsburg Code § 156-6

Related Rules

§ 244.290
Dwelling plumbing facilities required
§ 244.300
Shared bath dwelling unit plumbing facilities required
§ 244.310
Basement water closet

Source Information

Snapshot SHA:
Fetched:Nov 10, 2026, 12:01 AM UTC