Great Neck, N.Y., Code of Ordinances ch. 321 (eCode360 ed. 2026) § 321-38

Air conditioning and mechanical ventilation in multiple dwellings

In Force
Verified 11/10/2026 · Next check 12/10/2026
Great NeckSpecific Conditions

Operative Text

Great Neck, N.Y., Code of Ordinances ch. 321 (eCode360 ed. 2026) § 321-38
A. Refrigerants. (1) Refrigerants that are highly flammable shall not be used in multiple dwellings. (2) Direct systems using refrigerants that are flammable or toxic shall not be used for air-conditioning purposes. B. Ventilating systems. (1) Ventilating systems shall be installed and maintained so that the rapid spread of heat, flame or smoke through the system will be prevented and so that under conditions of use the temperature of any combustible material adjacent thereto or in contact therewith will not exceed a safe temperature. (2) Stairways, passageways, exits, shafts, hoistways or attics shall not be used as plenum chambers. (3) Ducts shall be securely fastened in place and appropriately fire-stopped. (4) Ducts and other air-handling equipment shall be of noncombustible material. (5) Filters shall be installed and maintained so as not to constitute a fire or smoke hazard. (6) Ducts passing through or located within combustible construction shall be separated from such construction by a clearance of at least 1/2 inch or by a noncombustible insulating material at least 1/4 inch thick. (7) Air required for ventilation shall be taken from the exterior or shall be quality-controlled. (8) Exhaust air from a dwelling unit or a space whose contents may emit odors, fumes or vapors shall not be circulated to other occupied spaces within the building. C. Air intake and exhaust openings. (1) Air intake and exhaust openings shall be installed, located and maintained so as not to constitute a hazard or nuisance and so as to prevent the possibility of fire, smoke, fumes or foreign matter being drawn into the system. (2) Ventilating systems shall be provided with adequate openings for incoming and outgoing air to obtain the required circulation. Intake openings shall provide air from an uncontaminated source. (3) Where openings for mechanical exhaust are located in spaces that also contain fuel-burning equipment, there shall be provided fixed intake openings from the exterior to supply sufficient air so that the fuel-burning equipment is not adversely affected. (4) Exhaust openings shall be located so that the exhaust air will not create a nuisance. D. Ventilation requirements. (1) Enclosures or spaces where heat, gases, vapors or odors may accumulate and become a potential source of hazard or nuisance shall be provided with adequate means of ventilation to remove such excess. (2) Public spaces shall be provided with means for obtaining air supply for the maximum number of persons for which such spaces are designed. E. Safety controls. (1) Manually operated controls shall be provided to stop the operation of all central fan equipment. Such controls shall be conspicuously identified and in readily accessible locations outside the fan room. (2) Every system using recirculated air and serving an assembly space or more than one fire area or more than one story of a building shall be provided with controls arranged so that under abnormal rise in temperature of the air in the system the fans causing normal circulation shall stop and require manual restart. (3) Every system for ventilating an assembly space shall be provided with an emergency switch conveniently located and with a durable sign giving instructions for shutting down the system in case of fire.
Source: Legislative text reproduced verbatim
Plain English

Great Neck, N.Y., Code of Ordinances ch. 321 § 321-38 establishes fire, smoke, and air-quality safety standards for air conditioning and mechanical ventilation systems in multiple dwellings. The provision prohibits the use of highly flammable or toxic refrigerants, requires that ductwork, filters, and air-handling equipment be made of noncombustible materials and properly maintained, and mandates that exhaust air from one unit not be recirculated to other occupied spaces. It also requires that ventilation systems include safety controls—such as manual shutoffs and automatic temperature-triggered fan stops—to limit the spread of fire, smoke, and hazardous fumes throughout a building.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 9, 2026

Plain English — not legal advice.

For Property Managers

Operators of multiple dwellings subject to Great Neck, N.Y., Code of Ordinances ch. 321 § 321-38 generally ensure that all HVAC and ventilation equipment is installed with noncombustible materials, that ducts are properly fire-stopped and secured, and that refrigerants used in the building are neither highly flammable nor toxic. Compliant operators also maintain filters and air intake openings so they do not create fire or smoke hazards, and verify that exhaust air from individual units or odor-producing spaces is never recirculated to other occupied areas. Safety controls—including conspicuously labeled manual shutoffs outside fan rooms and automatic temperature-triggered stops for systems serving assembly spaces or multiple fire areas—are typically kept functional and accessible at all times.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Under Great Neck, N.Y., Code of Ordinances ch. 321 § 321-38, tenants in multiple dwellings have an interest in knowing that their building's ventilation and air conditioning systems must meet specific fire safety and air-quality standards, including protections against the spread of smoke, fumes, and hazardous exhaust between units. If a tenant observes conditions that may indicate noncompliance—such as odors or fumes appearing to enter from other units through ventilation, or safety controls that appear missing or inaccessible—those observations may be relevant to a housing complaint or code enforcement inquiry. Tenants can generally report potential violations to the local building or code enforcement department, or consult a tenant-rights organization familiar with Great Neck housing regulations for guidance on available options.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 9, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

Rules and statutes that cite this regulation

Great Neck Code § 321-42

Related Rules

§ 244.290
Dwelling plumbing facilities required
§ 244.300
Shared bath dwelling unit plumbing facilities required
§ 244.310
Basement water closet

Source Information

Snapshot SHA:
Fetched:Nov 9, 2026, 07:53 PM UTC