Highland Falls, N.Y., Code of Ordinances ch. 122 (eCode360 ed. 2026) § 122-31
Electrical standards
Operative Text
A. General requirements. (1) Electrical wiring and equipment shall be installed in conformity with generally accepted standards and maintained so as not to be a potential source of ignition of combustible material or a potential source of electrical hazard. (2) Electrical wiring and equipment shall be firmly secured to the surface on which it is mounted. (3) Electrical wiring and equipment installed in damp or wet locations or where exposed to explosive or flammable gases or to excessive temperatures shall be of a type approved for the purpose and location. (4) Electrical wiring and equipment shall be protected against excessive current by properly rated overcurrent devices. (5) Electrical wiring and equipment shall be grounded or otherwise protected by insulation, isolation or guarding so as to minimize the danger of high voltages from lightning or other sources. (6) Electrical equipment which in ordinary operation produces arcs or sparks shall be enclosed unless separated and isolated from all combustible material. (7) Service equipment and overcurrent protection devices shall be installed and maintained in a readily accessible location. B. Artificial lighting. (1) Residential buildings and occupancies shall be wired for electricity, and lighting equipment shall be installed throughout to provide adequate illumination for the intended use of each space. The electric wiring system shall be connected to an adequate source of supply. (2) There shall be a switch or other means for controlling a light in each dwelling unit near the point of entrance to such unit. C. Exit and directional signs. (1) Exits in multiple dwellings shall be provided with exit and directional signs, visible from the approach to the exits, except that such signs shall not be required in those portions of a building which contain dwelling units only or in which exit from sleeping rooms is directly to the outside. (2) Directional signs shall be provided at locations from which the exit doorway is not readily discernible. (3) Such signs shall be worded in plainly legible block letters with the word "exit" for exit signs and the words "to exit" with a suitable pointer or arrow indicating the direction of exit for directional signs. Letters for signs shall be conspicuous, readily discernible and at least six inches high, except that for internally illuminated signs the height of such letters shall be at least 4 1/2 inches. (4) Exit and directional signs shall be illuminated either externally or internally by electric lights and shall be kept illuminated at all times when the building is occupied.
Highland Falls, N.Y., Code of Ordinances ch. 122 § 122-31 establishes comprehensive electrical standards for residential buildings, covering everything from safe installation and grounding of wiring and equipment to adequate artificial lighting in each dwelling unit. The provision also requires that multiple dwellings display properly worded, illuminated exit and directional signs visible from the approach to exits whenever the building is occupied. Together, these requirements are designed to reduce fire hazards, electrical dangers, and risks to occupant safety during emergencies.
Plain English — not legal advice.
Under § 122-31, compliant property owners and managers generally ensure that all electrical wiring and equipment is installed to accepted standards, firmly secured, properly grounded, and protected by correctly rated overcurrent devices kept in accessible locations. Operators of residential buildings also confirm that each dwelling unit has adequate lighting with a switch near the entrance, and that the building's electrical system connects to an adequate power source. For multiple dwellings, maintaining continuously illuminated exit and directional signs with block letters at least six inches high (or 4½ inches for internally illuminated signs) is a standard part of ongoing building upkeep under this section.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
Section 122-31 of the Highland Falls Code gives tenants a basis to expect that their building's electrical wiring, equipment, and lighting meet safety standards, including proper grounding, overcurrent protection, and a light switch near each unit's entrance. Tenants in multiple dwellings can also expect clearly worded, illuminated exit and directional signs to be maintained whenever the building is occupied. Those who observe conditions that appear to fall short of these standards — such as exposed wiring, missing exit signs, or inaccessible electrical panels — may consider documenting the issue and reaching out to the local code enforcement or housing authority, or consulting a tenant-rights organization for guidance on available options.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated November 10, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.