Ithaca, N.Y., Code of Ordinances ch. 210 § 210-30

Air-conditioning and mechanical ventilation

In Force
Verified 11/7/2026 · Next check 2/5/2027
IthacaHabitability & Repair

Operative Text

Ithaca, N.Y., Code of Ordinances ch. 210 § 210-30
A. One- and two-family dwellings. (1) Exhaust air from a dwelling unit shall not be circulated to another dwelling unit. (2) Ducts shall be securely fastened in place and appropriately fire-stopped. B. Multiple dwellings. (1) Refrigerants. (a) Refrigerants that are highly flammable shall not be used in multiple dwellings. (b) Direct systems using refrigerants that are flammable or toxic shall not be used for air-conditioning purposes. (2) Ventilating systems. (a) Ventilating systems shall be installed and maintained so that the rapid spread of heat, flame or smoke through the system will be prevented and so that, under conditions of use, the temperature of any combustible material adjacent thereto or in contact therewith will not exceed a safe temperature. (b) Stairways, passageways, exits, shafts, hoistways or attics shall not be used as plenum chambers. (c) Ducts shall be securely fastened in place and appropriately fire-stopped. (d) Ducts and other air-handling equipment shall be of noncombustible material. (e) Filters shall be installed and maintained so as not to constitute a fire or smoke hazard. (f) Ducts passing through or located within combustible construction shall be separated from such construction by a clearance of at least 1/2 inch or by a noncombustible insulating material at least 1/4 inch thick. (g) Air required for ventilation shall be taken from the exterior or shall be quality-controlled. (h) Exhaust air from a dwelling unit or a space whose contents may emit odors, fumes or vapors shall not be circulated to other occupied spaces within the building. (3) Air intake and exhaust openings. (a) Air intake and exhaust openings shall be installed, located and maintained so as not to constitute a hazard or nuisance and so as to prevent the possibility of fire, smoke, fumes or foreign matter being drawn into the system. (b) Ventilating systems shall be provided with adequate openings for incoming and outgoing air to obtain the required circulation. Intake openings shall provide air from an uncontaminated source. (c) Where openings for mechanical exhaust are located in spaces that also contain fuel-burning equipment, there shall be provided fixed intake openings from the exterior to supply sufficient air so that the fuel-burning equipment is not adversely affected. (d) Exhaust openings shall be located so that the exhaust air will not create a nuisance. (4) Ventilation requirements. (a) Enclosures or spaces where heat, gases, vapors or odors may accumulate and become a potential source of hazard or nuisance shall be provided with adequate means of ventilation to remove such excess. (b) Public spaces shall be provided with means for obtaining air supply for the maximum number of persons for which such spaces are designed. (5) Safety controls. (a) Manually operated controls shall be provided to stop the operation of all central fan equipment. Such controls shall be conspicuously identified and in readily accessible locations outside the fan room. (b) Every system using recirculated air and serving an assembly space or more than one fire area or more than one story of a building shall be provided with controls arranged so that, under abnormal rise in temperature of the air in the system, the fans causing normal circulation shall stop and require manual restart. (c) Every system for ventilating an assembly space shall be provided with an emergency switch conveniently located and with a durable sign giving instructions for shutting down the system in case of fire.
Source: Legislative text reproduced verbatim
Plain English

Ithaca, N.Y., Code of Ordinances ch. 210 § 210-30 establishes safety standards for air-conditioning and mechanical ventilation systems in both one- and two-family dwellings and multiple dwellings. The rule prohibits practices that could spread fire, smoke, fumes, or toxic substances through a building's ventilation system, such as using highly flammable refrigerants, routing exhaust air into occupied spaces, or using stairways and exits as air plenums. It also requires that ducts, filters, intake openings, and safety controls be installed and maintained in ways that prevent fire hazards and protect occupants from contaminated air.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 7, 2026

Plain English — not legal advice.

For Property Managers

Property owners and managers subject to § 210-30 generally ensure that all ductwork is securely fastened and fire-stopped, that materials used in air-handling systems are noncombustible, and that filters are kept in a condition that does not pose a fire or smoke hazard. In multiple dwellings, compliant operators verify that refrigerants meet the flammability and toxicity restrictions stated in the ordinance and that exhaust air from any unit or odor-producing space is never recirculated to other occupied areas. Operators of buildings with central fan systems also maintain manually operated emergency shutoff controls that are conspicuously labeled and accessible outside the fan room, as required by § 210-30(B)(5).

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Under § 210-30, tenants in Ithaca have a right to ventilation systems that do not expose them to another unit's exhaust air, flammable refrigerants, or fire and smoke hazards from improperly installed ductwork or filters. If a tenant believes a ventilation system in their building violates these standards—for example, if exhaust odors from another unit are entering their space or ductwork appears unsecured—they may consider documenting the condition and reporting it to the City of Ithaca's code enforcement office. Tenants can also consult a local tenant-rights organization to understand how a violation of § 210-30 might be raised in a housing proceeding or complaint process.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 7, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

No inbound references recorded yet for this provision.