Jamestown, N.Y., Code of Ordinances ch. 215 § 215-25

Smoke detectors

In Force
Verified 11/7/2026 · Next check 2/5/2027
JamestownHabitability & Repair

Operative Text

Jamestown, N.Y., Code of Ordinances ch. 215 § 215-25
An approved single-station smoke detector continuously powered by the house electrical service shall be installed in an approved manner in every living unit within a building containing three or more separate dwelling units. In one- and two-family dwellings a battery-operated or electric smoke detector shall be installed in an approved manner near each sleeping area. When activated, the detector shall initiate an alarm which is audible in the sleeping rooms of each unit. This individual-station smoke detector shall be in addition to any sprinkler system or other detection system that may be installed in the building.
Source: Legislative text reproduced verbatim
Plain English

Section 215-25 of Jamestown's Code of Ordinances establishes smoke detector requirements that vary by building type. In buildings with three or more dwelling units, each unit must have a hardwired, electrically powered smoke detector installed in an approved manner. In one- and two-family homes, a battery-operated or electric detector must be placed near each sleeping area, and any detector that activates must produce an alarm loud enough to be heard in the sleeping rooms of that unit. These individual detectors are required regardless of whether the building also has a sprinkler or other fire detection system.

Written by anthropic/claude-sonnet-4.6 · Reviewed on November 7, 2026

Plain English — not legal advice.

For Property Managers

Operators of rental properties in Jamestown should be familiar with § 215-25, which sets distinct installation standards depending on the number of units in a building. In properties with three or more dwelling units, compliant operators ensure that each living unit contains a continuously powered, hardwired smoke detector installed according to approved methods. In one- and two-family rental properties, compliant operators place battery-operated or electric detectors near every sleeping area and verify that the alarm signal is audible within the sleeping rooms of each unit, keeping these detectors in place even when a sprinkler or broader detection system is also present.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Section 215-25 gives tenants in Jamestown the right to have functioning smoke detectors installed in their dwelling units according to standards set by local code. Tenants in buildings with three or more units are entitled to a hardwired detector in their unit, while those in one- or two-family homes are entitled to a detector near each sleeping area with an audible alarm. Tenants who believe their unit lacks a required detector may consider documenting the condition, contacting local code enforcement or housing authorities, or reaching out to a tenant-rights organization for guidance on available options.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated November 7, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.

Effective Timeline

Click on timeline segments to view historical versions.

References Out

No outbound references recorded yet for this provision.

References In

No inbound references recorded yet for this provision.

Related Rules

§ 244.260
Compliance required
§ 14.567
ADOPTED BY REFERENCE
§ 244.340
Sewer and water connections

Source Information

Snapshot SHA:
Fetched:Nov 7, 2026, 08:25 AM UTC