Syracuse, N.Y., Rev. Gen. Ord. ch. 27 § 27-161

Design requirements

In Force
Verified 10/12/2026 · Next check 11/11/2026
SyracuseState Accessibility Codes

Operative Text

Syracuse, N.Y., Rev. Gen. Ord. ch. 27 § 27-161
In addition to the mandated requirements of the New York State Uniform Fire Prevention and Building Code, the common council encourages that the following design standards be applied to each newly constructed single-, two- and three-family dwelling unit: (a)
Accessible route to the dwelling. The route is to be located on a continuous unobstructed path from the public street, driveway, sidewalk or garage that serves the unit. It must be accessible to and usable by people with disabilities and do not contain stairs or any door thresholds that exceed one-half (½) inch in height. Any thresholds above that should be beveled. It must be served by a slope or a ramp, in compliance with ICC/ANSI A117.1-2003 with a maximum slope of 1:12, and have a width of thirty-six (36) inches minimum, unless it is impractical due to characteristics of the terrain. Exception: the finished grade of the site is too steep to provide a 1:12 route of travel.
(b) Accessible dwelling entrance. Applicable dwelling units shall be designed and constructed to have one no-step dwelling entrance on an accessible route. This entrance should have an accessible door in accordance with ICC/ANSI A117.12003 and minimum clearance of thirty-six (36) inches. Any entrance at the front, side or back of the dwelling is acceptable.
The aforementioned requirement may be waived by the city of Syracuse Commissioner of Neighborhood and Business Development or his/her designee by issuing and "Exterior Accessibility Waiver" only in instances of site impracticability. The individual requesting such waiver shall file an application for the waiver, which shall provide proof that the topographical conditions of the building site prevent complying with the above access feature despite proper grading and site preparation to improve accessibility. An independent party shall make a verification of the site's impracticability. A good faith attempt must be made on the part of a developer to improve accessibility of the site.
(c) Accessible interior door criteria. All doors that are designed to allow passage within the ground level shall have an unobstructed opening of thirty-six (36) inches when the door is open at ninety (90) degree angle. Doors should be operated with a minimum strength and effort in accordance with ICC/ANSI A117.1-2003. Lever handles arc preferred on all ground floor doorways.
(d) Accessible route throughout the ground floor of the dwelling. An accessible route shall be designed and constructed in such a manner that a thirty-six (36) inches wide, level route must be provided throughout the ground floor of the dwelling with ramped or beveled changes at the thresholds, creating an interior circulation path between the dwelling entrance and the interior spaces in accordance with ICC/ANSI A117.1-2003.
(e) Bathroom on the ground floor with accessible features. A bathroom on the ground floor should contain the following features in accordance with ICC/ANSI A117.1-2003:
(1) Clear floor space of a five-foot turn around radius, with a clear floor space of thirty (30) by forty-eight (48) inches centered on and contiguous to the sink, not encroached by the swing path of the bathroom door.
(2) A sink and a toilet that each allow for parallel or head-on approach by a wheelchair user.
(3) Walls that are reinforced for future grab bar installation that resist forced of a minimum of at least two hundred fifty (250) pounds as follows.
a. All walls adjacent to the toilet shall have horizontal backing reinforcements, each at least thirty-three (33) inches, but not more than thirty-six (36) inches, above the floor, and sufficient to allow for a twenty-four (24) inch grab bar on the wall behind the toilet and another forty-two (42) inch grab bar on the other walls adjacent to the toilet.
b. If a bathtub is present, such reinforcements shall include a two (2) backing reinforcements on the back wall of the bathtub, each at least twenty-four (24) inches long and not more than twenty-four (24) from the head end wall and no more than twelve (12) inches from the foot end wall; one in a horizontal position at least thirty three (33) inches, but no more than thirty-six (36) inches, above the floor; and one nine (9) inches above the rim of the bathtub; one backing reinforcement on the foot end wall of the bathtub, at least twenty-four (24) inches long and located at the front edge of the bathtub; and one backing reinforcement on the head end wall of the bathtub, at least twelve (12) inches long and located at the front edge of the bathtub.
c. If a shower is present in the bathroom, such reinforcements shall include backing reinforcements on at least two walls on which the control valve is not located, each at least thirty-three (33) inches, but not more than thirty-six (36) inches, above the floor.
(f) Light switches, electrical controls, thermostats and other environmental controls in accessible locations. All applicable dwellings shall be designed and constructed in such a manner that all premises contain light switches, electrical outlets, thermostats and other controls are in accessible locations, located no higher than forty-eight (48) inches and no lower than fifteen (15) inches from the floor, and in accordance with ICC/ANSI A117.1-2003.
(g) Usable ground floor kitchen with wheelchair maneuvering clearances and accessible food preparation area. Clear floor space of a five-foot turn around radius, with a clear floor space of thirty (30) by forty-eight (48) inches centered on and contiguous to the sink, not encroached by the swing path of the bathroom door. This should be accomplished as set forth by the (ICC) ANSI A117.1-2003.
(h) Accessible habitable space on the ground floor that could be used as a bedroom. The space should contain at least one indoor room that has an area of not less than seventy (70) square feet and contains no side or dimension narrower than seven (7) feet in accordance with ICC/ANSI A117.1-2003.
Source: Legislative text reproduced verbatim
Plain English

Syracuse Rev. Gen. Ord. ch. 27, art. 11 § 27-161 sets out a series of design standards that the Syracuse Common Council encourages—but does not strictly mandate—for newly built one-, two-, and three-family homes, layered on top of New York State's Uniform Fire Prevention and Building Code. The standards address accessible routes from the street, step-free entrances, wide interior doorways, ground-floor circulation paths, accessible bathrooms and kitchens, reachable controls, and usable ground-floor bedroom space, all generally aligned with ICC/ANSI A117.1-2003 specifications. A waiver of the exterior accessibility features is available from the city's Commissioner of Neighborhood and Business Development when site topography makes compliance genuinely impractical, provided an independent verification is obtained and a good-faith effort to improve accessibility is documented.

Written by anthropic/claude-sonnet-4.6 · Reviewed on October 14, 2026

Plain English — not legal advice.

For Property Managers

Builders and developers working on new single-, two-, and three-family construction in Syracuse should be aware that § 27-161 articulates a set of encouraged accessibility design standards covering accessible routes, no-step entrances, 36-inch interior door clearances, ground-floor bathroom reinforcements, reachable controls, and accessible kitchen and bedroom spaces. Compliant operators typically document how each design element meets or approaches the ICC/ANSI A117.1-2003 benchmarks referenced throughout the provision. Where steep terrain makes an accessible exterior route infeasible, operators generally pursue the formal 'Exterior Accessibility Waiver' process through the Commissioner of Neighborhood and Business Development, including an independent site-impracticability verification and evidence of good-faith grading efforts.

General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.

For Tenants

Tenants considering or occupying a newly constructed one-, two-, or three-family home in Syracuse may find § 27-161 relevant if accessibility features—such as a step-free entrance, wide doorways, or an accessible ground-floor bathroom—were represented as part of the unit's design. Because the provision frames these standards as encouraged rather than strictly required, the practical weight of any specific feature may depend on how it was incorporated into the building permit or sales representations. Individuals who believe accessibility commitments were not honored can explore options such as contacting the city's Department of Neighborhood and Business Development, consulting a tenant-rights or disability-rights organization, or reviewing whether the waiver process under § 27-161 was properly followed.

General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.

Generated October 14, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.