Watervliet, N.Y., Code of Ordinances ch. 175 § 175-48
Fuel oil
Operative Text
A. General requirements. Fuel oil shall be received, stored and conveyed by means of fixed liquidtight equipment. B. Storage tanks. (1) Tanks shall be provided with a means for venting. (2) Tanks shall be installed and maintained so as not to be a hazard to the premises served or the surrounding property. C. Piping. (1) Automatically operated boilers and furnaces using fuel oil shall be provided with a remote control to stop the flow of oil during a fire or other emergency. (2) Filling, emptying and venting of tanks shall be by means of fixed piping. Pipes to underground tanks shall be pitched toward tanks. Terminals of fill and vent pipes shall be located outside buildings at a safe distance from building openings.
Section 175-48 of the Watervliet Code of Ordinances establishes safety standards for how fuel oil is handled on residential and commercial premises. The rule requires that fuel oil be received, stored, and moved only through sealed, liquid-tight equipment, and that storage tanks be properly vented and installed so they do not pose a hazard to nearby property. Piping connected to underground tanks must slope toward the tank, and fill and vent pipe openings must be located outside buildings at a safe distance from any building openings; additionally, automatically operated boilers and furnaces must have a remote shutoff control accessible during emergencies.
Plain English — not legal advice.
Property owners and managers operating fuel oil systems in Watervliet should ensure that all equipment covered by § 175-48 — including tanks, piping, and boilers or furnaces — is installed and maintained in full conformance with the ordinance's requirements. Compliant operators typically verify that storage tanks are equipped with functioning vents, that underground tank piping is pitched correctly toward the tank, and that fill and vent pipe terminals are positioned outside the building at a safe distance from openings. Operators of automatically controlled boilers or furnaces generally confirm that a remote oil-flow shutoff control is in place and accessible in the event of a fire or other emergency.
General guidance for property managers — not legal advice for your specific situation. Consult an attorney for advice on your case.
Tenants living in buildings with fuel oil heating systems have an interest in knowing that § 175-48 of the Watervliet Code of Ordinances sets baseline safety standards for how that fuel is stored and delivered. If a tenant observes conditions that appear to violate these requirements — such as improperly located fill pipes, missing vents, or the absence of an emergency shutoff — they may consider reporting the concern to the appropriate Watervliet code enforcement or building inspection office. Tenant-rights organizations can help residents understand what documentation to gather and what local complaint processes may be available.
General guidance for tenants — not legal advice for your specific situation. Consult a tenant-rights organization or attorney for advice on your case.
Generated November 7, 2026 — auto-generated, not yet human-reviewed. See /transparency for methodology.